U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

NOTICE UPDATED - April, 25th 2024

NIST has updated the NVD program announcement page with additional information regarding recent concerns and the temporary delays in enrichment efforts.

CVE-2024-0220 Detail

Description

B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data. Missing Encryption of Sensitive Data, Cleartext Transmission of Sensitive Information, Improper Control of Generation of Code ('Code Injection'), Inadequate Encryption Strength vulnerability in B&R Industrial Automation B&R Automation Studio (Upgrade Service modules), B&R Industrial Automation Technology Guarding.This issue affects B&R Automation Studio: <4.6; Technology Guarding: <1.4.0.


Severity



CVSS 4.0 Severity and Metrics:

NIST CVSS score
NIST: NVD
N/A
NVD assessment not yet provided.


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: NVD Analysts have not published a CVSS score for this CVE at this time. NVD Analysts use publicly available information at the time of analysis to associate CVSS vector strings.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf

Weakness Enumeration

CWE-ID CWE Name Source
CWE-311 Missing Encryption of Sensitive Data Provider acceptance level Asea Brown Boveri Ltd. (ABB)  
CWE-319 Cleartext Transmission of Sensitive Information Provider acceptance level Asea Brown Boveri Ltd. (ABB)  
CWE-94 Improper Control of Generation of Code ('Code Injection') Provider acceptance level Asea Brown Boveri Ltd. (ABB)  
CWE-326 Inadequate Encryption Strength Provider acceptance level Asea Brown Boveri Ltd. (ABB)  

Change History

2 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2024-0220
NVD Published Date:
02/22/2024
NVD Last Modified:
02/22/2024
Source:
Asea Brown Boveri Ltd. (ABB)