You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
NIST has updated the
NVD program announcement page with additional information regarding
recent concerns and the temporary delays in enrichment efforts.
CVE-2023-4464
Detail
Modified
This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided.
Current Description
A vulnerability, which was classified as critical, has been found in Poly Trio 8300, Trio 8500, Trio 8800, Trio C60, CCX 350, CCX 400, CCX 500, CCX 505, CCX 600, CCX 700, EDGE E100, EDGE E220, EDGE E300, EDGE E320, EDGE E350, EDGE E400, EDGE E450, EDGE E500, EDGE E550, VVX 101, VVX 150, VVX 201, VVX 250, VVX 300, VVX 301, VVX 310, VVX 311, VVX 350, VVX 400, VVX 401, VVX 410, VVX 411, VVX 450, VVX 500, VVX 501, VVX 600 and VVX 601. This issue affects some unknown processing of the component Diagnostic Telnet Mode. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The identifier VDB-249257 was assigned to this vulnerability.
A vulnerability, which was classified as critical, has been found in Poly CCX 400, CCX 600, Trio 8800 and Trio C60. This issue affects some unknown processing of the component Diagnostic Telnet Mode. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The identifier VDB-249257 was assigned to this vulnerability.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have not published a CVSS score for this CVE at this time. NVD Analysts use publicly available information at the time of analysis to associate CVSS vector strings.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: The NVD and the CNA have provided the same score. When this occurs only the CNA information is displayed, but the Acceptance Level icon for the CNA is given a checkmark to signify NVD concurrence.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have not published a CVSS score for this CVE at this time. NVD Analysts use publicly available information at the time of analysis to associate CVSS vector strings. A CNA provided score within the CVE List has been displayed.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
A vulnerability, which was classified as critical, has been found in Poly CCX 400, CCX 600, Trio 8800 and Trio C60. This issue affects some unknown processing of the component Diagnostic Telnet Mode. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The identifier VDB-249257 was assigned to this vulnerability.
AND
OR
*cpe:2.3:o:poly:ccx_400_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:poly:ccx_400:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:poly:ccx_600_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:poly:ccx_600:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:poly:trio_8800_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:poly:trio_8800:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:poly:trio_c60_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:poly:trio_c60:-:*:*:*:*:*:*:*
Added
CVSS V3.1
NIST AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Changed
Reference Type
https://fahrplan.events.ccc.de/congress/2023/fahrplan/events/11919.html No Types Assigned
https://fahrplan.events.ccc.de/congress/2023/fahrplan/events/11919.html Not Applicable
Changed
Reference Type
https://modzero.com/en/advisories/mz-23-01-poly-voip-devices/ No Types Assigned
https://modzero.com/en/advisories/mz-23-01-poly-voip-devices/ Broken Link
Changed
Reference Type
https://vuldb.com/?ctiid.249257 No Types Assigned
https://vuldb.com/?ctiid.249257 Permissions Required, Third Party Advisory, VDB Entry
Changed
Reference Type
https://vuldb.com/?id.249257 No Types Assigned
https://vuldb.com/?id.249257 Third Party Advisory, VDB Entry
New CVE Received by NIST12/29/2023 5:15:11 AM
Action
Type
Old Value
New Value
Added
CVSS V2
VulDB (AV:N/AC:L/Au:M/C:C/I:C/A:C)
Added
CVSS V3.1
VulDB AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Added
CWE
VulDB CWE-78
Added
Description
A vulnerability, which was classified as critical, has been found in Poly CCX 400, CCX 600, Trio 8800 and Trio C60. This issue affects some unknown processing of the component Diagnostic Telnet Mode. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The identifier VDB-249257 was assigned to this vulnerability.