NIST is currently working to establish a consortium to address challenges in the NVD program and develop improved tools and methods. You will temporarily see delays in analysis efforts during this transition. We apologize for the inconvenience and ask for your patience as we work to improve the NVD program.

CVE-2019-6260 Detail

Description

The ASPEED ast2400 and ast2500 Baseband Management Controller (BMC) hardware and firmware implement Advanced High-performance Bus (AHB) bridges, which allow arbitrary read and write access to the BMC's physical address space from the host (or from the network in unusual cases where the BMC console uart is attached to a serial concentrator). This CVE applies to the specific cases of iLPC2AHB bridge Pt I, iLPC2AHB bridge Pt II, PCIe VGA P2A bridge, DMA from/to arbitrary BMC memory via X-DMA, UART-based SoC Debug interface, LPC2AHB bridge, PCIe BMC P2A bridge, and Watchdog setup.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  9.8 CRITICAL
Vector:  CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://security.netapp.com/advisory/ntap-20190314-0001/ Patch  Third Party Advisory 
https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-785 Third Party Advisory 
https://www.flamingspork.com/blog/2019/01/23/cve-2019-6260:-gaining-control-of-bmc-from-the-host-processor/ Third Party Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
NVD-CWE-noinfo Insufficient Information cwe source acceptance level NIST  

Known Affected Software Configurations Switch to CPE 2.2