Description

Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before V1.0.0.75, D6100 before V1.0.0.63, R7800 before v1.0.2.52, R8900 before v1.0.4.2, R9000 before v1.0.4.2, RBK50 before v2.3.0.32, RBR50 before v2.3.0.32, RBS50 before v2.3.0.32, WNDR3700v4 before V1.0.2.102, WNDR4300v1 before V1.0.2.104, WNDR4300v2 before v1.0.0.58, WNDR4500v3 before v1.0.0.58, WNR2000v5 before v1.0.0.68, and XR500 before V2.3.2.32.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  6.8 MEDIUM
Vector:  CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Nist CVSS score does not match with CNA score
CNA:  MITRE
Base Score:  6.8 MEDIUM
Vector:  CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://kb.netgear.com/000061191/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2018-0138 Vendor Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-787 Out-of-bounds Write cwe source acceptance level NIST  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

1 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2019-20735
NVD Published Date:
04/16/2020
NVD Last Modified:
04/23/2020
Source:
MITRE