CVE-2021-40336 Detail

Description

A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user’s web browser, such as to steal the session cookies. Thus, an attacker who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., the link is sent per E-Mail, could trick the user into downloading malicious software onto his computer. This issue affects: Hitachi Energy MSM V2.2 and prior versions.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  8.8 HIGH
Vector:  CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Nist CVSS score does not match with CNA score
CNA:  Hitachi ABB Power Grids
Base Score:  5.0 MEDIUM
Vector:  CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://search.abb.com/library/Download.aspx?DocumentID=8DBD000085&LanguageCode=en&DocumentPartId=&Action=Launch Vendor Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') cwe source acceptance level NIST  
CWE-113 Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Request/Response Splitting') Reference acceptance level Hitachi ABB Power Grids  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

4 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2021-40336
NVD Published Date:
07/25/2022
NVD Last Modified:
06/26/2023
Source:
Hitachi ABB Power Grids