CVE-2021-22779 Detail
Modified
This CVE record has been updated after NVD enrichment efforts were completed. Enrichment data supplied by the NVD may require amendment due to these changes. DescriptionAuthentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller. Metrics 
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
CVSS 3.x Severity and Vector Strings:
References to Advisories, Solutions, and ToolsBy selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.
Weakness Enumeration
Known Affected Software Configurations Switch to CPE 2.2 Configuration 1 ( hide )
Configuration 2 ( hide )
Configuration 3 ( hide )
Configuration 4 ( hide )
Configuration 5 ( hide )
Configuration 6 ( hide )
Configuration 7 ( hide )
Configuration 8 ( hide )
Configuration 9 ( hide )
Configuration 10 ( hide )
Configuration 11 ( hide )
Configuration 12 ( hide )
Configuration 13 ( hide )
Configuration 14 ( hide )
Configuration 15 ( hide )
Configuration 16 ( hide )
Configuration 17 ( hide )
Configuration 18 ( hide )
Configuration 19 ( hide )
Configuration 20 ( hide )
Configuration 21 ( hide )
Configuration 22 ( hide )
Configuration 23 ( hide )
Configuration 24 ( hide )
Configuration 25 ( hide )
Configuration 26 ( hide )
Configuration 27 ( hide )
Configuration 28 ( hide )
Configuration 29 ( hide )
Configuration 30 ( hide )
Denotes Vulnerable Software Quick InfoCVE Dictionary Entry:CVE-2021-22779 NVD Published Date: 07/14/2021 NVD Last Modified: 11/21/2024 Source: Schneider Electric SE |