CVE-2021-20586 Detail
Modified
This CVE record has been updated after NVD enrichment efforts were completed. Enrichment data supplied by the NVD may require amendment due to these changes. DescriptionResource management errors vulnerability in a robot controller of MELFA FR Series(controller "CR800-*V*D" of RV-*FR***-D-* all versions, controller "CR800-*HD" of RH-*FRH***-D-* all versions, controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller "CR800-CVD" of RV-8CRL-D-* all versions, controller "CR800-CHD" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller "CR800-05VD" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs. Metrics
NVD enrichment efforts reference publicly available information to associate
vector strings. CVSS information contributed by other sources is also
displayed.
CVSS 3.x Severity and Vector Strings:
References to Advisories, Solutions, and ToolsBy selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.
Weakness Enumeration
Known Affected Software Configurations Switch to CPE 2.2 Configuration 1 ( hide )
Configuration 2 ( hide )
Configuration 3 ( hide )
Configuration 4 ( hide )
Configuration 5 ( hide )
Configuration 6 ( hide )
Configuration 7 ( hide )
Configuration 8 ( hide )
Configuration 9 ( hide )
Configuration 10 ( hide )
Configuration 11 ( hide )
Configuration 12 ( hide )
Configuration 13 ( hide )
Configuration 14 ( hide )
Configuration 15 ( hide )
Configuration 16 ( hide )
Configuration 17 ( hide )
Configuration 18 ( hide )
Configuration 19 ( hide )
Configuration 20 ( hide )
Configuration 21 ( hide )
Configuration 22 ( hide )
Configuration 23 ( hide )
Configuration 24 ( hide )
Configuration 25 ( hide )
Configuration 26 ( hide )
Configuration 27 ( hide )
Configuration 28 ( hide )
Configuration 29 ( hide )
Configuration 30 ( hide )
Configuration 31 ( hide )
Configuration 32 ( hide )
Configuration 33 ( hide )
Denotes Vulnerable Software Quick InfoCVE Dictionary Entry:CVE-2021-20586 NVD Published Date: 01/29/2021 NVD Last Modified: 11/21/2024 Source: Mitsubishi Electric Corporation |