You are viewing this page in an unauthorized frame window.
This is a potential security issue, you are being redirected to
https://nvd.nist.gov
An official website of the United States government
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock () or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
NIST has updated the
NVD program announcement page with additional information regarding
recent concerns and the temporary delays in enrichment efforts.
CVE-2020-16216
Detail
Modified
This vulnerability has been modified since it was last analyzed by the NVD. It is awaiting reanalysis which may result in further changes to the information provided.
Current Description
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to nvd@nist.gov.
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
AND
OR
*cpe:2.3:o:philips:intellivue_mp2-mp90_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mp2-mp90:n:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx100:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx400:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx550:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx600_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx600:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx700:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx750_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx750:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx800:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_mx850_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_mx850:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_x2:n:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*
OR
cpe:2.3:h:philips:intellivue_x3:n:*:*:*:*:*:*:*
Added
CPE Configuration
OR
*cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:*
*cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*
*cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*
*cpe:2.3:a:philips:performancebridge_focal_point:a.01:*:*:*:*:*:*:*
Added
CVSS V2
NIST (AV:A/AC:L/Au:N/C:N/I:N/A:C)
Added
CVSS V3.1
NIST AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Changed
Reference Type
https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 No Types Assigned
https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 Third Party Advisory, US Government Resource
Quick Info
CVE Dictionary Entry: CVE-2020-16216 NVD
Published Date: 09/11/2020 NVD
Last Modified: 12/12/2023
Source: ICS-CERT