Description

On EX4300, EX4600, QFX3500, and QFX5100 Series, a vulnerability in the IP firewall filter component may cause the firewall filter evaluation of certain packets to fail. This issue only affects firewall filter evaluation of certain packets destined to the device Routing Engine (RE). This issue does not affect the Layer 2 firewall filter evaluation nor does it affect the Layer 3 firewall filter evaluation destined to connected hosts. This issue may occur when evaluating both IPv4 or IPv6 packets. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D12 on QFX5100 Series and EX4600 Series; 14.1X53 versions prior to 14.1X53-D52 on QFX3500 Series; 14.1X53 versions prior to 14.1X53-D48 on EX4300 Series; 15.1 versions prior to 15.1R7-S3 on EX4300 Series; 16.1 versions prior to 16.1R7 on EX4300 Series; 17.1 versions prior to 17.1R3 on EX4300 Series; 17.2 versions prior to 17.2R3 on EX4300 Series; 17.3 versions prior to 17.3R2-S5, 17.3R3 on EX4300 Series; 17.4 versions prior to 17.4R2 on EX4300 Series; 18.1 versions prior to 18.1R3 on EX4300 Series; 18.2 versions prior to 18.2R2 on EX4300 Series.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  5.3 MEDIUM
Vector:  CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N

Nist CVSS score does not match with CNA score
CNA:  Juniper Networks, Inc.
Base Score:  6.5 MEDIUM
Vector:  CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://kb.juniper.net/JSA10983 Vendor Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
NVD-CWE-noinfo Insufficient Information cwe source acceptance level NIST  
CWE-284 Improper Access Control Reference acceptance level Juniper Networks, Inc.  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

2 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2020-1604
NVD Published Date:
01/15/2020
NVD Last Modified:
11/18/2021
Source:
Juniper Networks, Inc.