U.S. flag   An official website of the United States government
Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock (Dot gov) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

NOTICE UPDATE

NIST has updated the NVD program announcement page with additional information regarding recent concerns and the temporary delays in enrichment efforts.

CVE-2019-1767 Detail

Description

A vulnerability in the implementation of a specific CLI command for Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to cause a buffer overflow condition or perform command injection. This could allow the attacker to execute arbitrary commands with elevated privileges on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to a certain CLI command. An attacker could exploit this vulnerability by including malicious input as the argument of the affected CLI command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with root privileges. An attacker would need valid administrator credentials to exploit these vulnerabilities. NX-OS versions prior to 8.3(1) are affected.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  6.7 MEDIUM
Vector:  CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Nist CVSS score does not match with CNA score
CNA:  Cisco Systems, Inc.
Base Score:  6.7 MEDIUM
Vector:  CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
http://www.securityfocus.com/bid/108386 Third Party Advisory  VDB Entry 
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-overflow-inj Vendor Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') cwe source acceptance level NIST  
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Reference acceptance level Cisco Systems, Inc.  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

6 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2019-1767
NVD Published Date:
05/15/2019
NVD Last Modified:
10/16/2020
Source:
Cisco Systems, Inc.