NIST is currently working to establish a consortium to address challenges in the NVD program and develop improved tools and methods. You will temporarily see delays in analysis efforts during this transition. We apologize for the inconvenience and ask for your patience as we work to improve the NVD program.

CVE-2017-17436 Detail

Description

An issue was discovered in the software on Vaultek Gun Safe VT20i products. There is no encryption of the session between the Android application and the safe. The website and marketing materials advertise that this communication channel is encrypted with "Highest Level Bluetooth Encryption" and "Data transmissions are secure via AES256 bit encryption." These claims, however, are not true. Moreover, AES256 bit encryption is not supported in the Bluetooth Low Energy (BLE) standard, so it would have to be at the application level. This lack of encryption allows an individual to learn the passcode by eavesdropping on the communications between the application and the safe.


Severity



CVSS 3.x Severity and Metrics:

NIST CVSS score
NIST: NVD
Base Score:  8.8 HIGH
Vector:  CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H


NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.

Note: NVD Analysts have published a CVSS score for this CVE based on publicly available information at the time of analysis. The CNA has not provided a score within the CVE List.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to nvd@nist.gov.

Hyperlink Resource
https://vaulteksafe.com/index.php/cve-2017-17435/ Mitigation  Vendor Advisory 
https://www.twosixlabs.com/bluesteal-popping-gatt-safes/ Third Party Advisory 

Weakness Enumeration

CWE-ID CWE Name Source
CWE-326 Inadequate Encryption Strength cwe source acceptance level NIST  

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

2 change records found show changes

Quick Info

CVE Dictionary Entry:
CVE-2017-17436
NVD Published Date:
12/06/2017
NVD Last Modified:
12/22/2017
Source:
MITRE